We use cookies to make your experience better. To comply with the new e-Privacy directive, we need to ask for your consent to set the cookies. Learn more.
R&S®MXO 5 Oscilloscope
Next generation oscilloscope: evolved for more challenges
Key facts
- Bandwidth: 4 channel: 350 MHz - 2 GHz | 8 channel: 100 MHz - 2 GHz
- World’s fastest oscilloscope with > 4.5 million wfms/s update rate and spectrum with > 45k FFT/s
- Industry-leading architecture: 18-bit vertical resolution/12-bit ADC and 10-bit ENOB
- Zone trigger on analog, spectrum and math
- Deepest in class standard memory: 500 Mpoints
Next generation oscilloscope: evolved for more challenges
The R&S®MXO 5 series delivers breakthrough oscilloscope technology to speed up understanding and testing of electronic systems.
The specifications for both the 4 and 8 channel models make the R&S®MXO 5 series the industry leader in cutting-edge technology for swift and precise results. The oscilloscopes' advanced customized technology and revolutionary features are indispensable for insight into circuit behavior. The impressive 15.6" Full HD capacitive touchscreen and whisper-soft audible operating noise maximize R&S®MXO 5 series performance and minimize power consumption.
Get the big picture faster
… with evolving accelerated insights
- World's first 8-channel oscilloscope to achieve > 4.5 million acquisitions/s
- World's first 8-channel oscilloscope to achieve 18 million waveforms/s across multiple channels
- Up to 90% real-time signal capture
- Simultaneous 4 × FFT spectrum analysis
See your signals accurately
… with lowest noise and highest vertical resolution on up
to 8 channels
- Uncompromising 12-bit ADC for high vertical resolution at all sample rates
- 18-bit architecture with HD mode
- Low noise of 130 μV at 1 mV/div at full bandwidth of 2 GHz
- Full bandwidth vertical scaling down to 500 uV/div with highest offset range of 5 V
Capture even more time
… with the deepest standard memory
- Industry’s deepest memory of 500 Mpoints per channel
- Standard segmented memory 10,000 segments
- Standard history mode with 10,000 acquisitions
- Optional memory extension to 1 Gpoints per channel with 1 million segment/memory acquisitions
Trigger on every detail
… with high-precision digital trigger
- World's first 8-channel oscilloscope with trigger sensitivity down to 0.0001 vertical
divisions - World's first 8-channel oscilloscope with adjustable trigger hysteresis
- World’s fastest trigger rearm time of < 21 ns
- Zone trigger on analog, spectrum and math
- Best in class trigger jitter of just 1 ps
Multispectral evolution
... with even more capabilities
- World's first 8-channel oscilloscope with 4 spectra as well as independent time and frequency controls
- World's first 8-channel oscilloscope with up to 45,000 FFT/s
- RF and time domain views with independent controls
- Industry best spectrum capabilities and zone trigger come standard with each R&S®MXO 5 series
Model | Description |
---|---|
R&S®MXO54-350 | 4 channel oscilloscope bandwidth 350 MHz upgradable bandwidth to 500 MHz, 1 GHz, and 2 GHz - 12-bit ADC & 18-bit in HD mode - 4.5 Mwfms/s acquisition rate - 500 Mpts acquisition memory - 5 Gsample/s sample rate - 4 passive 700 MHz probes |
R&S®MXO54-500 | Package MXO 5 series 4 channel oscilloscope, 500 MHz Contains serialized product+options: R&S®MXO 5 series oscilloscope 4 channels 1802.1008K04 consisting of: - R&S®MXO 5 series oscilloscope 4 channel - R&S®MXO5-B245 500 MHz bandwidth upgrade |
R&S®MXO54-1000 | Package MXO 5 series 4 channel oscilloscope, 1 GHz Contains serialized product+options: R&S®MXO 5 series oscilloscope 4 channels 1802.1008K04 consisting of: - R&S®MXO 5 series oscilloscope 4 channels - R&S®MXO5-B2410 1 GHz bandwidth upgrade |
R&S®MXO54-2000 | Package MXO 5 series 4 channel oscilloscope, 2 GHz Contains serialized product+options: R&S®MXO 5 series oscilloscope 4 channels 1802.1008K04 consisting of: - R&S®MXO 5 series oscilloscope 4 channels - R&S®MXO5-B2420 2 GHz bandwidth upgrade |
R&S®MXO58-100 | Package MXO 5 series 8 channel oscilloscope, 100 MHz Contains serialized product: R&S®MXO 5 series oscilloscope 8 channels 1335.5050K08 consisting of: - R&S®MXO 5 series oscilloscope 8 channels, 100 MHz Bandwidth |
R&S®MXO58-200 | Package MXO 5 series 8 channel oscilloscope, 200 MHz Contains serialized product+options: R&S®MXO 5 series oscilloscope 8 channels 1802.1008K08 consisting of: - R&S®MXO 5 series oscilloscope 8 channels - R&S®MXO5-B282 200 MHz bandwidth upgrade |
R&S®MXO58-350 | Package MXO 5 series 8 channel oscilloscope, 350 MHz Contains serialized product+options: R&S®MXO 5 series oscilloscope 8 channels 1802.1008K08 consisting of: - R&S®MXO 5 series oscilloscope 8 channels - R&S®MXO5-B283 350 MHz bandwidth upgrade |
R&S®MXO58-500 | Package MXO 5 series 8 channel oscilloscope, 500 MHz Contains serialized product+options: R&S®MXO 5 series oscilloscope 8 channels 1802.1008K08 consisting of: - R&S®MXO 5 series oscilloscope 8 channels - R&S®MXO5-B285 500 MHz bandwidth upgrade |
R&S®MXO58-1000 | Package MXO 5 series 8 channel oscilloscope, 1 GHz Contains serialized product+options: R&S®MXO 5 series oscilloscope 8 channels 1802.1008K08 consisting of: - R&S®MXO 5 series oscilloscope 8 channels - R&S®MXO5-B2810 1 GHz bandwidth upgrade |
R&S®MXO58-2000 | Package MXO 5 series 8 channel oscilloscope, 2 GHz Contains serialized product+options: R&S®MXO 5 series oscilloscope 8 channels 1802.1008K08 consisting of: - R&S®MXO 5 series oscilloscope 8 channels - R&S®MXO5-B2820 2 GHz bandwidth upgrade |
Customize your new R&S®MXO 5 Oscilloscope
Choose your hardware options
Model | Description |
---|---|
General |
|
MXO5-B1 | Mixed signal option for R&S®MXO 5 series with 16 digital channels |
MXO5-B6 | Arbitrary waveform generator, 100 MHz, 2 analog channels |
MXO5-B19 | Additional replacement SSD |
Memory upgrade |
|
MXO5-B110 | Memory upgrade to 1Gpoint |
Choose your software options
Model | Description |
---|---|
General analysis |
|
MXO5-K31 | Power analysis |
MXO5-K36 | Frequency response analysis (requires MXO5-B6 as source) |
Serial triggering and decoding |
|
MXO5-K510 | Low speed serial protocol: Trigger/decode: I2C, SPI, UART, RS-232/422/485 Decode: Quad-SPI |
MXO5-K520 | Automotive serial protocol: CAN, CAN-FD, CAN-XL, LIN |
MXO5-K550 | MIPI low speed protocol: SPMI serial decode |
MXO5-K560 | Automotive ethernet decode package: 10BASE-T1S and 100BASE-T1 |
Bundles |
|
MXO5-PK1 | Application bundle with the following options: R&S®MXO5-K510, R&S®MXO5-K520, R&S®MXO5-K31, R&S®MXO5-K36, R&S®MXO5-B6 |
Choose your accessories
Model | Description |
---|---|
MXO5-Z1 | Front cover: protects the front of the R&S®MXO 5 oscilloscope |
MXO5-Z3 | Soft case stores the R&S®MXO 5 oscilloscope and accessories |
MXO5-Z4 | Transit case with trolley function for R&S® MXO 5 series oscilloscopes and accessories (accessory) |
MXO5-Z7 | VESA mount adapter |
ZZA-MXO5 | Rackmount kit for R&S®MXO 5 oscilloscopes with 8 HU |
Choose your probes
Model | Description |
---|---|
Passive probes |
|
RT-ZP05S | Passive probe, 500 MHz, 10:1 |
RT-ZP1X | Passive probe, 38 MHz, 1:1 |
RT-ZP10 | Passive probe, 500 MHz, 10:1 |
RT-ZP11 | Passive probe, 700 MHz, 10:1 |
Active single-ended probes |
|
RT-ZS10E | Active single-ended probe, 1 GHz, Rohde & Schwarz probe interface |
RT-ZS10 | Active single-ended probe, 1 GHz, R&S®ProbeMeter, Rohde & Schwarz probe interface |
RT-ZS20 | Active single-ended probe, 1.5 GHz, R&S®ProbeMeter, Rohde & Schwarz probe interface |
Active differential probes |
|
RT-ZD10 | Active differential probe, 1 GHz, Rohde & Schwarz probe interface |
RT-ZD20 | Active differential probe, 1.5 GHz, Rohde & Schwarz probe interface |
RT-ZD30 | Active differential probe, 3.0 GHz, Rohde & Schwarz probe interface |
Power rail probes |
|
RT-ZPR20 | Power rail probe, 2 GHz, R&S®ProbeMeter, Rohde & Schwarz probe interface |
High voltage probes |
|
RT-ZH03 | 250 MHz passive high voltage probe |
RT-ZH10 | 400 MHz passive high voltage probe |
RT-ZH11 | 400 MHz passive high voltage probe |
RT-ZHD07 | 200 MHz High voltage differential probe |
RT-ZHD15 | 100 MHz High voltage differential probe |
RT-ZHD16 | 200 MHz High voltage differential probe |
RT-ZHD60 | 100 MHz High voltage differential probe |
Current probes |
|
RT-ZC02 | AC/DC 20 kHz current probe |
RT-ZC10 | 10 MHZ current probe |
RT-ZC15B | 50 MHZ Current probe |
RT-ZC10B | 10 MHZ Current probe |
RT-ZC20 | 100 MHZ current probe |
RT-ZC20B | 100 MHZ current probe |
RT-ZC30 | 120 MHz current probe |
RT-ZC31 | 120 MHz current probe |
RT-ZC03 | 100 kHz current probe |
Modular probe system |
|
RT-ZM15 | Modular probe amplifier module, 1.5 GHz |
RT-ZM30 | Modular probe amplifier module, 3 GHz |
Logic probes |
|
RT-ZL04 | 400 MHz logic probe |
EMC near field probes |
|
HZ-15 | E and H near-field probe set |
Probe Accessories |
|
RT-ZA1 | Accessory kit for passive probes RT(M)-ZP10/ ZP11/-ZP1X |
RT-ZA13 | Power supply for probes Power supply for R&S®RT-ZC10/20/30 probes, +/-12V DC, +/-2.5A |
RT-ZA15 | External attenuator 10:1, 2.0 GHz, 1.3 pF, 60 V DC, 42 V AC (peak) for R&S®RT-ZD20/30 probes. Included in R&S®RT-ZD10. |
RT-ZA19 | Accessory case for probes |
RT-ZA29 | Probe positioner with 2 legs |
RT-ZF20 | Power deskew fixture |
RT-ZAP | 3D probe positioner |
Upgrade your pre-purchased R&S®MXO 5 Oscilloscope
Choose your hardware options
Model | Description |
---|---|
General |
|
MXO5-B1 | Mixed signal option for R&S®MXO 5 series with 16 digital channels |
MXO5-B6-unregistered | Arbitrary waveform generator, 100 MHz, 2 analog channels |
MXO5-B19 | Additional replacement SSD |
Memory upgrade |
|
MXO5-B110-unregistered | Memory upgrade to 800 Mpoints on 2 channels |
Bandwidth upgrade |
|
MXO5-B245-unregistered | Upgrade of R&S®MXO 5 series oscilloscopes with 4 channels and up to 500 MHz bandwidth |
MXO5-B2410-unregistered | Upgrade 4-channel R&S®MXO 5 series oscilloscope to 1 GHz bandwidth |
MXO5-B2420-unregistered | Upgrade 4-channel R&S®MXO 5 series oscilloscope to 2 GHz bandwidth |
MXO5-B282-unregistered | Upgrade of 8-channel R&S®MXO 5 series oscilloscope to 200 MHz bandwidth |
MXO5-B283-unregistered | Upgrade of 8-channel R&S®MXO 5 series oscilloscope to 350 MHz bandwidth |
MXO5-B285-unregistered | Upgrade of 8-channel R&S®MXO 5 series oscilloscope to 500 MHz bandwidth |
MXO5-B2810-unregistered | Upgrade of 8-channel R&S®MXO 5 series oscilloscope to 1 GHz bandwidth |
MXO5-B2820-unregistered | Upgrade of 8-channel R&S®MXO 5 series oscilloscope to 2 GHz bandwidth |
Choose your software options
Model | Description |
---|---|
General analysis |
|
MXO5-K31-unregistered | Power analysis |
MXO5-K36-unregistered | Frequency response analysis (requires MXO5-B6 as source) |
Serial triggering and decoding |
|
MXO5-K520-unregistered | Automotive serial protocol: CAN, CAN-FD, CAN-XL, LIN |
MXO5-K550-unregistered | MIPI low speed protocol: SPMI serial decode |
MXO5-K560-unregistered | Automotive ethernet decode package: 10BASE-T1S and 100BASE-T1 |
Bundles |
|
MXO5-PK1-unregistered | Application bundle with the following options: R&S®MXO5-K510, R&S®MXO5-K520, R&S®MXO5-K31, R&S®MXO5-K36, R&S®MXO5-B6 |
R&S® Extended Warranty
To make sure you get the full benefit from the functionality and precision of your instruments for the longest possible time, we offer a range of services that are tailored to your specific needs. Choose extended warranty (WE1 to WE4) for complete protection in case of repair, or the attractive extended warranty with calibration coverage package with R&S®Manufacturer-Calibration (CW1 to CW4) or with R&S®Accredited-Calibration (AW1 to AW4) for additional regular calibration of your instrument. The three options are available with terms of one to four years depending on the duration of the standard warranty.
Compare Rohde & Schwarz Extended Warranty Services
Description | Extended Warranty (WE1-4) |
Extended Warranty with Calibration Coverage (CW1-4) |
Extended Warranty with Accredited Calibration Coverage (AW1-4) |
---|---|---|---|
Repair in case of malfunction All repairs during the warranty periodare free of charge. |
|
|
|
Calibration if necessary as part of repair All necessary calibrations will be made during the repair. |
R&S® Manufacturer- Calibration |
R&S® Manufacturer- Calibration |
R&S®Accredited- Calibration |
Planned calibrations in line with Rohde & Schwarz guidelines and ISO/IEC 17025 With our precision test and diagnostics systems we analyze your equipment in detail, to detect and correct irregularities before they impact your measurments. Your instruments stay in top working condition. |
R&S® Manufacturer- Calibration |
R&S®Accredited- Calibration |
|
Calibration as needed as part of hardware upgrades We take care that your Rohde & Schwarz product is regularly calibrated and maintained at the recommended intervals during the warranty period, including also calibrations as part of hardware upgrades to the latest technologies. |
R&S® Manufacturer- Calibration |
R&S®Accredited- Calibration |
|
Firmware updates As part of regular checks, we will update your instrument’s firmware to improve product characteristics, enhance system performance and bring all functions up to date. |
|
|
|
Preventive maintenance and reliability modifications To improve the performance and reliability of your instrument, we maintain it with the greatest care and precision. This naturally includes hardware updates, a service that only the manufacturer can offer. |
|
|
|
Contact us to add any of this services to your R&S products. Click here to read R&S extended warranty brochure. |
R&S® Service Contracts
To make sure you get the full benefit from the functionality and precision of your instruments for the longest possible time, we offer a range of services that are tailored to your specific needs. Choose one of the following packages. All are available with terms of one to five years.
Compare Rohde & Schwarz Services Contracts
Coverage | Repairs | Calibration (R&S® recommended intervals) |
Calibration (R&S® recommended intervals) and repairs |
||
---|---|---|---|---|---|
Product | R1-R5 | C1-C5 | A1-A5 | RC1-RC5 | AR1-AR5 |
Includes | Repair Coverage |
R&S® Manufacturer Calibration | R&S® Accredited Calibration | R&S® Manufacturer Calibration and Repair Coverage | R&S® Accredited Calibration and Repair Coverage |
Repairs |
|
|
|
||
Calibration needed during repair |
|
|
|
|
|
Scheduled calibration in line with Rohde & Schwarz guidelines and ISO/IEC 17025 |
|
|
|
|
|
Calibration as required due to technical upgrade |
|
|
|
|
|
Calibration adjustments for optimimum, reliable performance |
|
|
|
|
|
Firmware updates |
|
|
|
|
|
Preventative maintenance and service modifications |
|
|
|
|
|
If you would prefer to have different contract durations or calibration intervals, or to add any of this services to your R&S products, please Contact us. Click here to read R&S service contracts brochure. |
Service that adds value
- Local and personalized
- Customized and flexible
- Uncompromising quality
- Long-term dependability
Adding services to your order? Contact us for more details.