COVID-19: Customer Information & Supplier Updates - Stay Informed

RSA607A 04

SKU
TEK-RSA607A04-A-1

Optional tracking generator for gain/loss, antenna and cable measurements

Tracking generator (Option 04) 

•Frequency range: 10 MHz to 7.5 GHz 
•Sweep speed: 6700 MHz/second, 101 points, 50 kHz RBW (11 mS per point) [Measured using a Panasonic Toughpad FZ-G1, Intel® Core™ i5-5300U 2.3 GHz Processor, 8 GB RAM, 256 GB SSD, Windows®7 Pro.] 
•Frequency resolution: 100 Hz 
•TG output connector: N type 
•VSWR: < 1.8:1, 10 MHz to 7.5 GHz, -20 dBm output level Maximum output power: -3 dBm
•Output power level setting range: 40 dB
•Output power level step size: 1 dB
•Output power level step size accuracy: ± 0.5 dB
•Output level accuracy: ± 1.5 dB, 10 MHz to 7.5 GHz, -20 dBm output level
•Harmonics: < -22 dBc
•Non-harmonic spurious: < -30 dBc; spurious < 2 GHz from TG output frequency
•< -25 dBc; spurious ≥ 2 GHz from TG output frequency
•Reverse power without damage: 40 Vdc, +20 dBm RF
•Transmission gain measurement error: Gain of +20 to -40 dB: ±1 dB
•Transmission gain measurement dynamic range: 70 dB

 

The RSA600A Series USB spectrum analyzers offer high performance portable spectrum analysis in a rugged battery-powered package.

Features and benefits:

  • 9 kHz to 3.0/7.5 GHz frequency range covers a broad range of analysis needs
  • 40 MHz acquisition bandwidth enables real time analysis for transient capture and vector analysis
  • Amplitude accuracy of 0.2 dB to 3 GHz (95% confidence)
  • Standard GPS/GLONASS/Beidou receiver
  • Optional tracking generator for gain/loss, antenna and cable measurements
  • Streaming capture can be used to record and play back long term events
  • SignalVu-PC software offers real time signal processing with DPX Spectrum/Spectrogram to minimize time spent finding transient problems
  • 27 μsec minimum signal duration with 100% probability of intercept ensure you see problems first time, every time
  • Application programming interface included for development of custom programs
  • Accessories including tablet PC, calibration kits, adapters and phasestable cables offer a complete solution for design, characterization, and manufacturing
Frequently Bought Together
50

array(50) { [0]=> string(4) "4393" [1]=> string(4) "4394" [2]=> string(4) "4395" [3]=> string(4) "4396" [4]=> string(4) "4397" [5]=> string(4) "4398" [6]=> string(4) "4399" [7]=> string(4) "4400" [8]=> string(4) "4401" [9]=> string(4) "4402" [10]=> string(4) "4403" [11]=> string(4) "4406" [12]=> string(4) "4407" [13]=> string(4) "4408" [14]=> string(4) "4409" [15]=> string(4) "4410" [16]=> string(4) "4418" [17]=> string(4) "4423" [18]=> string(4) "4424" [19]=> string(4) "4425" [20]=> string(4) "4426" [21]=> string(4) "4427" [22]=> string(4) "4428" [23]=> string(4) "4429" [24]=> string(4) "4430" [25]=> string(4) "4431" [26]=> string(4) "4432" [27]=> string(4) "4433" [28]=> string(4) "4434" [29]=> string(4) "4435" [30]=> string(4) "4436" [31]=> string(4) "4444" [32]=> string(4) "4446" [33]=> string(4) "4447" [34]=> string(4) "4448" [35]=> string(4) "4449" [36]=> string(4) "4450" [37]=> string(4) "4451" [38]=> string(4) "4452" [39]=> string(4) "4453" [40]=> string(4) "4455" [41]=> string(4) "4456" [42]=> string(4) "4457" [43]=> string(4) "4458" [44]=> string(4) "4496" [45]=> string(4) "4497" [46]=> string(4) "4499" [47]=> string(4) "4500" [48]=> string(4) "4526" [49]=> string(4) "4527" }

array(2) { [31]=> string(4) "4444" [33]=> string(4) "4447" }